LHE7904G

The LHE7904, LHE7906 and LHE7908 (collectively referred to as the LHE790X series) are multi-channel synchronous sampling 24-bit Δ-Σ analog-to-digital converters (ADCs) integrating programmable gain amplifiers (PGAs), an internal voltage reference and an internal oscillator. The LHE790X series incorporates all core functions commonly required for electrocardiogram (ECG) and electroencephalogram (EEG) medical applications. Featuring high integration and superior performance, the LHE790X enables the development of scalable medical instrument systems with drastically reduced footprint, power consumption and overall system cost. Each channel of the LHE790X is equipped with a flexible input multiplexer (MUX), which can be individually routed to internally generated signals for self-testing, temperature measurement and lead-off detection. In addition, any configuration of input channels can be selected to generate a right-leg drive (RLD) output signal. The LHE790X supports a maximum operating data rate of 64 kSPS and integrates a hardware pace detection algorithm. Lead-off detection can be implemented on-chip via pull-up/pull-down resistors or excitation current sources. Three integrated amplifiers are available to generate the Wilson Central Terminal (WCT) and Goldberger Central Terminal (GCT), which are essential for standard 12-lead ECG systems. Multiple LHE790X devices can be cascaded in a daisy-chain configuration for high-channel-count systems. Available packages include a miniature 64-ball BGA package (8 mm × 8 mm) and an LQFP-64 package. The commercial-grade BGA variant of the LHE790X is rated for an operating temperature range of 0°C to 70°C, while the industrial-grade variant supports a temperature range of -40°C to +85°C.
LHE7904G

Product Features

• 8 low-noise programmable gain amplifiers (PGAs) and 8 high-resolution analog-to-digital converters (ADCs) (LHE790X)

• Low power consumption: 0.73 mW per channel

• Ultra-low power mode: 0.4 mW per channel

• Input-referred noise: 2.3 μVPP (150 Hz bandwidth (BW), Gain = 6)

• Input bias current: 500 pA

• Data rate: 250 SPS to 64 kSPS

• Common-mode rejection ratio (CMRR): –120 dB

• Programmable gain options: 1, 2, 3, 4, 6, 8, 12, 24

• Compatible with systems complying with AAMI EC11, EC13, IEC60601-1, IEC60601-2-27 and IEC60601-2-51 standards

• Unipolar or bipolar power supply: – AVDD: 2.7 V ~ 5.25 V – DVDD: 1.65 V ~ 5.25 V

• Integrated right-leg drive amplifier, lead-off detection, Wilson Central Terminal, pace detection and test signal generation

• Enhanced DC lead-off function and AC lead-off impedance detection

• User-friendly hardware pace detection algorithm interface

• On-chip oscillator and voltage reference

• SPI interface

Application Scenario

• Medical instruments (Electrocardiogram (ECG), Electromyogram (EMG), Electroencephalogram (EEG)): patient monitors, Holter monitors, vital signs detection devices; applicable to ECG equipment, AED, telemedicine, Bispectral Index (BIS), Evoked Auditory Potential (EAP), sleep monitors.