legendsemi

LHE3302

The LHE3302/LHE3301 are ultra-low-power programmable analog front-end (AFE) ICs that deliver complete bias voltage generation and measurement channels for electrochemical sensors. The LHE3302 features two independent DC measurement channels, compatible with 2-electrode, 3-electrode and 4-electrode sensors. The LHE3301 is equipped with one independent DC measurement channel for 2-electrode and 3-electrode sensor applications. The sensor electrode bias voltage can be flexibly adjusted via a 12-bit digital-to-analog converter (DAC), and the on-chip 16-bit analog-to-digital converter (ADC) quantizes sensor current. The supply voltage ranges from 1.7 V to 3.6 V, and the minimum bias operating current is as low as 3.5 μA. An integrated on-chip temperature sensor and bias voltage monitoring circuit safeguard sensor operating safety. The LHE3302/LHE3301 support a 256-byte FIFO buffer and 4-wire SPI serial communication interface. The operating temperature range spans −40 °C to +85 °C. Available packages include a 16-ball WLCSP (1.6 mm × 2 mm) and a 20-pin QFN (3 mm × 3 mm).
LHE3302

Product Features

• Supports 2 independent DC measurement channels

– Dual 12-bit voltage DACs (LHE3302 only)

– Single 16-bit ADC

– Configurable TIA resistors: 100 kΩ / 200 kΩ / 500 kΩ / 1 MΩ / 3 MΩ / 5 MΩ / 10 MΩ

– Maximum temperature sensor measurement error: ±0.5 °C

– On-chip 1.536 V / 2.048 V voltage references with temperature drift of 10 ppm/°C

• 1 channel of 12-bit DAC for adjustable DC bias voltage

• Ultra-low-power design

– Single-sensor bias mode: 3.4 μA

– Dual-sensor bias mode: 4.2 μA

– ADC continuous conversion @ 62.5 SPS: 15 μA

– Power-down mode: < 20 nA

• 256-depth FIFO buffer

• Digital interface: 4-wire SPI, maximum clock frequency up to 8 MHz

• Supply voltage VDD: 1.7 V ~ 3.6 V

• Package specifications

– 16-ball WLCSP: 1.6 mm × 2 mm, 0.4 mm ball pitch

– 20-pin QFN: 3 mm × 3 mm, 0.4 mm pin pitch

• Safety & compliance feature

– The 16-bit ADC supports sensor voltage and supply voltage monitoring

Application Scenario

• Electrochemical Sensors

• Continuous Glucose Monitoring (CGM)

• Electrochemical Gas Sensor Monitoring